Public Decontamination Station Configuration: Decontamination tent, electric inflation/deflation pump, decontamination water supply pump, decontamination sewage pump, integrated decontamination heating unit, decontamination solution mixing tank, warm air generator, decontamination wastewater collection bag, self-raising water bladder, and lighting lamp.
Decontamination Tent: Area ≥30 m², wind resistance 6–8 on the Beaufort scale, operating temperature range -30°C to +65°C, inflation time 5 to 10 minutes.
Electric Inflation/Deflation Pump: Power supply: 220 V, power ≥1800 W.
Decontamination Water Supply Pump: Power ≥1 kW, voltage 220 V, flow rate ≥65 L/min.
Decontamination Sewage Pump: Minimum water level drawdown ≤6 mm, motor power ≥0.5 kW, flow rate ≥6000 L/h.
Integrated Decontamination Heating Unit: Rapidly supplies hot water for shower decontamination with adjustable temperature. Flow rate ≥15 L/min, water supply temperature 0–70°C, motor power ≥30 kW.
Decontamination Solution Mixing Tank: Mixing capacity 500–2500 L/h, mixing concentration 0.4–4%.
Warm Air Generator: Rated power ≥25 kW, air output ≥1100 m³/h, fuel consumption ≤2.9 L/h.
Decontamination Wastewater Collection Bag: Capacity ≥500 L.
Self-Raising Water Bladder: Capacity ≥500 L, used for temporary storage of clean water for the entire system; quick and easy deployment, robust structure.
Lighting Lamp: Power ≥45 W.

Copy product links
Long by picture save/share